Region AMERICA
    Version

    Model

    HRVW-685 T4F

    Three phase | Diesel |

    Model

    Powered by VOLVO

    Alternator STAMFORD

    Emissions TIER IV FINAL

    PRP
    ESP
    COP
    Power kVA
    687
    756
    Power kW
    550
    605
    Voltage Frequency Phase Alternator Connection type Generator set data sheet
    120/208 V 60 Hz Three phase HCI534F Star - Parallel Download
    120D/240 V 60 Hz Three phase HCI534F Delta-series Download
    277/480 V 60 Hz Three phase HCI534F Star-series Download
    347/600 V 60 Hz Three phase HCI534F Star-series Download
    • Engine Specifications 1,800 r.p.m.
    • Rated Engine Output: 595kW prp ; 655kW standby
    • Manufacturer: VOLVO
    • Model: TWD1673GE
    • Engine Type: 4-stroke diesel
    • Injection Type: Direct
    • Aspiration Type: Turbocharged and after-cooled
    • Number of cylinders and arrangement: 6-L
    • Bore and Stroke: 5.67 x 6.5 in
    • Displacement: 983.64 CID
    • Cooling System: Liquid (water + 50% glycol)
    • Lube Oil Specifications: 10W40 CJ4 / CK4 ACEA E9
    • Compression Ratio: 16.8:1
    • Total oil capacity including tubes, filters 12.68 Gal
    • Total coolant capacity: 25.36 Gal
    • Governor Type Electrical
    • Air Filter Type Dry
    • Inner diameter exhaust pipe: 102 in
    • Low coolant level sensor
    • EPA TIER 4 FINAL
    • DEF Tank
    • Air Filter Restriction Indicator
    • Crankcase Ventilation Filter
    • Extended Maintenance Interval up to 500 Hrs.
    • Coolant Drain Extension
    • 24V electrical system
    • Dry air filter (medium duty)
    • Hot parts protection
    • Moving parts protection
    • Hydronic heater (5 kw) (Optional)
    • Oil Pan Heater (Optional)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Star - Parallel
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Delta-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)
    • - SOUNDPROOFED VERSION.
    • Anti-leakage chassis, predisposed to retain liquids (retention tray)
    • Oversized chassis to protect the bodywork
    • Chassis with integrated fuel tank
    • Double-walled fuel tank
    • Fuel level gauge
    • External emergency stop switch
    • Bodywork made from high quality steel plate
    • Low noise emissions level
    • Full access for maintenance (water, oil and filters, no need to remove the canopy)
    • Reinforced lifting hooks for crane hoisting
    • Chassis ready for future mobile kit installation
    • 3-Way Fuel valve 3/8" (Optional)
    • Trailer prepared for road transportation (Optional)
    • Draw bar with ball coupling and ring (Optional)
    • - ELECTRICAL SYSTEM.
    • Battery Switch
    • Leakage detector
    • Shunt Trip on MLCB
    • MLCB Auxiliary Contacts
    • Distribution Panel 2000A
    • 6 Amp Battery charger, 12V DC, UL Listed (Optional)
    • 10 Amp battery charger, 12/24V DC, UL Listed (Optional)
    • Battery Blanket (Optional)
    • Control Panel Heater (Optional)
    • - EXHAUST SYSTEM.
    • Maximum exhaust temperature: 903.2 ºF
    • Exhaust Gas Flow: 291,982.00 cfs
    • Maximum allowed back pressure: 80.20 inH2O
    • - NECESSARY AMOUNT OF AIR.
    • Intake air flow: 30 scfm
    • Cooling Air Flow: 28,817 scfm
    • Alternator fan air flow: 2,780 scfm
    • - STARTING SYSTEM.
    • Starting power: 7 kW
    • Starting power: 9.39 HP
    • Recommended battery: 225 x 2 Ah
    • Auxiliary Voltage: 24 Vdc
    • Starter current peak: 850 A
    • Nominal starter current: 300 A
    • - FUEL SYSTEM
    • Fuel Oil Specifications: Diesel
    • Maximum power suction pump: 225 mm Hg
    • Maximum return feed pump: 150 mm Hg
    • Fuel Tank: 600 Gal
    • - DIMENSIONS.
    • Length: 200 in
    • Height: 112 in
    • Width: 81.1 in
    • Maximum shipping volume: 1053.08 ft3
    • Dry weight: 19,500 Lbs
    • Fuel tank capacity: 600 Gal
    • Autonomy: 25 Hours
    • Sound pressure level: 72 ± 2.4 dB(A)@7m

    Dimensions

    Dimensions
    Length508200.00
    Width20681.10
    Height285112.20

    Autonomy

     
     

    21 h

    Fuel capacity

    2,271.25

    599.61

    Request a Quote

    Request a Quote

    By filling in this form you consent to have your information processed and recorded on our system and for the management of your relationship as a user, client, or candidate for employment Hipowersystems.com.
    /privacy-policy/eng.html

     privacy policy *
    * Required fields
     

    Necessary

    Technical cookies are strictly necessary for our website to function and to be able to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not required in this regard.

    Statistics

    The analysis cookies allow us to study the navigation of the users of our website in general (for example, which sections of the page are the most visited, which services are used the most and if they work correctly, etc.). Based on the statistical information on navigation on our website, we can improve both the operation of the page itself and the different services it offers. Therefore, these cookies do not have an advertising purpose, but only serve to make our website work better, adapting to our users in general. By activating them you will contribute to this continuous improvement.

    Marketing

    Marketing cookies are used to track visitors on web pages. The intention is to show ads relevant and attractive to the individual user, and therefore more valuable to publishers and third-party advertisers.