    HIPOWER SYSTEMS SPARK-IGNITED STANDBY GENERATORS are an efficient, reliable and versatile source of electrical power that have been designed to operate in the most extreme working conditions. They are built combining an innovative design and the use of high quality materials that provide the user with the most dependable power that can be relied on for non-stop power with easy to operate controls. The HEAVY DUTY INDUSTRIAL SPARK-IGNITED  STANDBY PRODUCT LINE is powered by a radiator-cooled, industrial PSI Spark-Ignited engine that meets current Environmental Protection Agency (EPA)  exhaust emission regulations, and driving a single bearing, four-pole, three-phase alternator, with IP23 protection. The Emergency Power kW rating is given with a 125 degree°C alternator winding temperature rise.

    VIEW MODELS

    Powered by PSI  

    RANGE: HNI-80, 100, 125, 150 & 200 | 450, 500 | 650, 800 & 1000 kW

    Powered by FORD

     RANGE:  HNSG-25, 36, 50 & 63 kW 

    Available in voltages ranging from 240/120 1PH to 600/347 3PH. The Spark_Ignited Standby Series can support any low voltage stationary application.

    The HNI have the flexibility and capability, when appropriately optioned, to be able to run in different fuel configurations which are Liquid Propane, Liquid Propane Vapor, and Dual Fuel in addition to natural gas. 

    The HNI series are specifically designed for use with data management, healthcare, construction, or any other critical installation that requires a standby generator.

    DOWNLOAD BROCHURE

    POWERFUL FEATURES | TOP BRAND COMPONENTS

    RELIABLE ENGINE

    HIPOWER SYSTEMS uses Power Solutions International (PSI) as the preferred partner for the prime mover on the HNI series. The HNI-80 and HNI-100 are using the 5.7L turbocharged and 5.7L turbocharged intercooled engines while the HNI-125 and HNI-150 are using the 8.8L turbocharged and 8.8L turbocharged intercooled engines. All engines, used in the new HNI models, are designed for use at 1800 RPM in 60HZ emergency standby applications.  EPA-certified for emergency standby applications.


    The engines are coupled to four-pole Stamford Alternators with AS440 voltage regulators to provide excellent transient voltage response. However, if greater transient voltage response is required then the HNI series can be optioned with a permanent magnet generator and MX341 or MX321 voltage regulator.


    CONTROLLERS
    Genset functions are controlled through a Deepsea DSE 7410 MKII controller. The controller is an auto start control module suitable for a wide variety of single genset applications. The DSE7410 MKII has built in ethernet communication providing advanced remote monitoring as well as being able to be integrated into a building management system via MODBUS.

    CIRCUIT BREAKER OPTIONS

    • Thermal-Magnetic trip 80% and 100% rated  
    • LS/I Electronic trip 80% and 100% rated  
    • LSI Electronic trip 80% and 100% rated   
    • LSIG Electronic trip 80% and 100% rated  
    • Shunt Trip  
    • Auxiliary Contacts for Main & Secondary Breaker.   
    • Second Main Line Circuit Breaker  
    • Mechanical Lugs


    FUEL SYSTEM FLEXIBILITY

    The HNI have the flexibility and capability, when appropriately optioned, to be able to run in different fuel configurations which are Liquid Propane, Liquid Propane Vapor, and Dual Fuel in addition to natural gas. 

     “With Dual Fuel operation, meaning the genset's primary fuel source is natural gas and secondary fuel source is LP or LPV, this gives the customer the ability of using their existing natural gas supply to their building while also providing the security of having onsite fuel storage with liquid propane in the case of a disaster and the natural gas supply to the building has been shut-off”. EJ LeBlanc, Sales Engineer

    HIPOWER SYSTEMS' award-winning gas generator line leads the field in reliability, performance and durability. Our wide assortment of generator and enclosure features and options enables these models to meet every possible application and need.


    The HNI series is designed to be used in the stationary and specifying markets with options ranging from fuel types, enclosures, enclosure accessories, I/O expansions, and breaker types, along many other options creating an almost unlimited number of combinations to be able to meet almost any engineering specification.

    HNI 80 TO 200 | TECHNICAL SHEET

    Fast and Easy Servicing. 

    The HNI series were also designed for fast and easy servicing. The gensets has four access doors and easy access to the catalytic converter allowing the service technicians access to standard service points as well as oil and coolant drains. In addition, the enclosures are fabricated and assembled at HIPOWER’s Olathe, KS facility, using 11-gauge steel power coated with a finish that exceeds a 1400-hr salt spray test to ensure the requirements of the stationary market are met or surpassed.


    WE STAND BEHIND OUR SPARK-IGNITED SERIES.  We stand behind our HNI PRODUCT LINE with a strong 2 Years or 2,000 hours (whichever occurs first) parts & labor limited warranty. First year covers parts & labor, 2nd year covers parts only.

    Request Info

    Request Info

    By filling in this form you consent to have your information processed and recorded on our system and for the management of your relationship as a user, client, or candidate for employment Hipowersystems.com.
    /privacy-policy/eng.html

    Indicate the type of request

     privacy policy *
    * Required fields
     

    Necessary

    Technical cookies are strictly necessary for our website to function and to be able to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not required in this regard.

    Statistics

    The analysis cookies allow us to study the navigation of the users of our website in general (for example, which sections of the page are the most visited, which services are used the most and if they work correctly, etc.). Based on the statistical information on navigation on our website, we can improve both the operation of the page itself and the different services it offers. Therefore, these cookies do not have an advertising purpose, but only serve to make our website work better, adapting to our users in general. By activating them you will contribute to this continuous improvement.

    Marketing

    Marketing cookies are used to track visitors on web pages. The intention is to show ads relevant and attractive to the individual user, and therefore more valuable to publishers and third-party advertisers.