Region AMERICA

    Standby Power

    STANDBY SPARK-IGNITED

    STANDBY SPARK-IGNITED

    Phase
    Voltage
    Power
    Power range
     
    STANDBY SPARK-IGNITED

    < 1000 kW (ESP)

    STANDBY SPARK-IGNITED
    Models
    STANDBY SPARK-IGNITED
    < 1250 kVA
    < 1000 kW

    Discover our new Spark-Ignited standby series 

    Industrial strength.                Enhanced configurability. 

    Reliable standby performance.         


    HIPOWER SYSTEMS SPARK-IGNITED STANDBY GENERATORS are an efficient, reliable and versatile source of electrical power that have been designed to operate in the most extreme working conditions. They are built combining an innovative design and the use of high quality materials that provide the user with the most dependable power that can be relied on for non-stop power with easy to operate controls. The HEAVY DUTY INDUSTRIAL SPARK-IGNITED  STANDBY PRODUCT LINE is powered by a radiator-cooled, industrial PSI Spark-Ignited engine that meets current Environmental Protection Agency (EPA)  exhaust emission regulations, and driving a single bearing, four-pole, three-phase alternator, with IP23 protection. The Emergency Power kW rating is given with a 125 degree °C alternator winding temperature rise.

    VIEW MODELS

    POWERED BY ORIGIN

    HNI-30, 40, 50, 60 & 80 kW

    POWERED BY PSI

    HNI-100, 125, 150, 200, 250, 300, 350, 450, 500, 650, 800 & 1000 kW 

    5 NEW POWER NODES EXPANSION 

    Available in voltages ranging from 240/120 1PH to 600/347 3PH. The Spark-Ignited Standby Series can support any low voltage stationary application

    FUEL SYSTEM FLEXIBILITY

     Available in Natural Gas, LP, LPV, or Dual Fuel configurations — providing unmatched flexibility and resilience. No fuel derates needed between natural gas and propane up to the HNI 60.

    The HEAVY DUTY INDUSTRIAL | HNI SERIES  is engineered for critical applications, such as data management, healthcare, construction, and any installation where dependable standby power is essential.

    POWERFUL FEATURES | TOP BRAND COMPONENTS

    Reliable Engines

    New Power Nodes Expansion!

    HIPOWER SYSTEMS selected Origin Engines as the preferred prime mover partner for this range. The HNI-30 features the 3.6L naturally aspirated engine, while the HNI-40, HNI-50, HNI-60, and HNI-80 leverage the 3.6L turbocharged intercooled engine. All engines are EPA-certified for 60 Hz emergency standby applications and operate at 1800 RPM, utilizing E-controls Engines management software. Each model is coupled with four-pole Stamford alternators to deliver excellent transient voltage response, with an optional permanent magnet generator and MX341 or MX321 voltage regulator for applications requiring enhanced performance.

    HIPOWER SYSTEMS uses Power Solutions International (PSI) as the preferred partner for the prime mover on the HNI series. The HNI-100 and HNI-100 are using the 5.7L turbocharged and 5.7L turbocharged intercooled engines while the HNI-125 and HNI-150 are using the 8.8L turbocharged and 8.8L turbocharged intercooled engines. All engines, used in the new HNI models, are designed for use at 1800 RPM in 60HZ emergency standby applications.  EPA-certified for emergency standby applications.


    The engines are coupled to four-pole Stamford Alternators with AS440 voltage regulators to provide excellent transient voltage response. However, if greater transient voltage response is required then the HNI series can be optioned with a permanent magnet generator and MX341 or MX321 voltage regulator.


    CONTROLLERS
    Genset functions are controlled through a Deepsea DSE 7410 MKII controller. The controller is an auto start control module suitable for a wide variety of single genset applications. The DSE7410 MKII has built in ethernet communication providing advanced remote monitoring as well as being able to be integrated into a building management system via MODBUS.

    CIRCUIT BREAKER OPTIONS

    • Thermal-Magnetic trip 80% and 100% rated  
    • LS/I Electronic trip 80% and 100% rated  
    • LSI Electronic trip 80% and 100% rated   
    • LSIG Electronic trip 80% and 100% rated  
    • Shunt Trip  
    • Auxiliary Contacts for Main & Secondary Breaker.   
    • Second Main Line Circuit Breaker  
    • Mechanical Lugs


    FUEL SYSTEM FLEXIBILITY

    The HNI series offers exceptional flexibility, with the capability—when properly optioned—to operate on multiple fuel configurations, including natural gas, liquid propane, liquid propane vapor, and dual fuel. This versatility provides unmatched flexibility and resilience for critical standby applications. Additionally, no fuel derating is required between natural gas and propane models up to the HNI 60, ensuring consistent performance regardless of the selected fuel source.


     “With Dual Fuel operation, meaning the genset's primary fuel source is natural gas and secondary fuel source is LP or LPV, this gives the customer the ability of using their existing natural gas supply to their building while also providing the security of having onsite fuel storage with liquid propane in the case of a disaster and the natural gas supply to the building has been shut-off”. EJ LeBlanc, Sales Engineer

    FAST AND EASY SERVISING

    The HNI Series is engineered for fast, accessible service. Each model includes four access doors, and service-friendly oil and coolant drain points. The enclosure—fabricated and assembled at HIPOWER’s Olathe, KS facility—is constructed from 11-gauge steel and finished with a powder coat that exceeds a 1400-hour salt spray test, ensuring superior durability for stationary applications.

    “As with every HIPOWER generator, service accessibility is at the forefront of the HNI design,” said Rafael Acosta, President of HIPOWER SYSTEMS. “Without a consistent maintenance schedule, standby generators cannot perform when needed most. Ensuring easy access to common service points is critical to long-term reliability.”


    Spark-ignited 

    HNI SERIES designed

    to be used in the stationary and specifying markets with options ranging from fuel types, enclosures, enclosure accessories, I/O expansions, and breaker types, along many other options creating an almost unlimited number of combinations to be able to meet almost any engineering specification.


    WE STAND BEHIND OUR SPARK-IGNITED SERIES.  We stand behind our HNI PRODUCT LINE with a strong 2 Years or 2,000 hours (whichever occurs first) parts & labor limited warranty. First year covers parts & labor, 2nd year covers parts only.

    Request Info

    Request Info

    By filling in this form you consent to have your information processed and recorded on our system and for the management of your relationship as a user, client, or candidate for employment Hipowersystems.com.
    /privacy-policy/eng.html

    Indicate the type of request

     privacy policy *
    * Required fields