Select region and country
Diesel < 1375 kVA
Spark Ignited < 1175 kVA
Spark Ignited < 1000 kW
Diesel < 2000 kW
Resources
Downloads
We have detected that you are using Internet Explorer
For a better user experience on our website, we recommend that you access with another browser, such as
| Chrome | Firefox | Edge | Safari |
If you decide to continue browsing with Explorer, we inform you that many functionalities, menus, banners..., will not run correctly.
Hemos detectado que estás usando Internet Explorer
Para una mejor experiencia de uso en nuestra web, te recomentados que accedas con otro navegador, como por ejemplo
Si decides seguir navegando con Explorer, te advertimos que muchas utilidades, menús, etc de este website no funcionarán bien con él.
HIPOWER SYSTEMS uses Power Solutions International (PSI) as the preferred partner for the prime mover on the HNI series. The HNI-80 and HNI-100 are using the 5.7L turbocharged and 5.7L turbocharged intercooled engines while the HNI-125, 150 and HNI-200 are using the 8.8L turbocharged and 8.8L turbocharged intercooled engines. All engines, used in the new HNI models, are designed for use at 1800 RPM in 60HZ emergency standby applications. EPA-certified for emergency standby applications.
CONTROLLERSGenset functions are controlled through a Deepsea DSE 7410 MKII controller. The controller is an auto start control module suitable for a wide variety of single genset applications. The DSE7410 MKII has built in ethernet communication providing advanced remote monitoring as well as being able to be integrated into a building management system via MODBUS.
CIRCUIT BREAKER OPTIONS
The HNI-100 and HNI-150 have the flexibility and capability, when appropriately optioned, to be able to run in different fuel configurations which are Liquid Propane, Liquid Propane Vapor, and Dual Fuel in addition to natural gas.
“With Dual Fuel operation, meaning the genset’s primary fuel source is natural gas and secondary fuel source is LP or LPV, this gives the customer the ability of using their existing natural gas supply to their building while also providing the security of having onsite fuel storage with liquid propane in the case of a disaster and the natural gas supply to the building has been shut-off” - Said, EJ Leblanc - Sales Engineering Director.
FAST & EASY SERVICING.
The HNI series were also designed for fast and easy servicing. The gensets have four access doors and easy access to the catalytic converter allowing the service technicians access to standard service points as well as oil and coolant drains. In addition, the enclosures are fabricated and assembled at HIPOWER’s Olathe, KS facility, using 11-gauge steel powder coated with a finish that exceeds a 1400-hr salt spray test to ensure the requirements of the stationary market are met or surpassed.
“Just like in every HIPOWER generator, service accessibility is a forefront in the design process of the HNI series. Without a successful service schedule, emergency standby generators cannot provide power when it is needed most and therefore accessibility to common service items is critical to the success of that schedule.” said Rafael Acosta, President at HIPOWER SYSTEMS.
The HNI series are specifically designed for use with data management, healthcare, construction, or any other critical installation that requires a standby generator.
Available in voltages ranging from 240/120 1PH to 600/347 3PH, the HNI series can support any low voltage stationary application.
WE STAND BEHIND OUR SPARK-IGNITED SERIES.
We stand behind our HNI PRODUCT LINE with a strong 2 Years or 2,000 hours (whichever occurs first) parts & labor.
At HIPOWER, we make it easy.
Contact us today and experience the HIPOWER difference.
By filling in this form you consent to have your information processed and recorded on our system and for the management of your relationship as a user, client, or candidate for employment Hipowersystems.com. /privacy-policy/eng.html
Indicate the type of request
A cookie or computer cookie is a small information file that is saved on your computer, smartphone or tablet each time you visit our website. Some cookies are ours and others belong to external companies that provide services for our website. Cookies can be of various types: technical cookies are necessary for our website to function, they do not need your authorization and they are the only ones that we have activated by default. The rest of cookies are used to improve our page, to personalize it based on your preferences, or to be able to show you advertising tailored to your searches, tastes and personal interests. You can accept all these cookies by pressing the ALLOW ALL button, accept or reject their use by clicking on each of them and then on the ALLOW SELECTED button. Cookies Policy
Necessary Statistics Marketing Show details
Necessary
Technical cookies are strictly necessary for our website to function and to be able to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not required in this regard.
Statistics
The analysis cookies allow us to study the navigation of the users of our website in general (for example, which sections of the page are the most visited, which services are used the most and if they work correctly, etc.). Based on the statistical information on navigation on our website, we can improve both the operation of the page itself and the different services it offers. Therefore, these cookies do not have an advertising purpose, but only serve to make our website work better, adapting to our users in general. By activating them you will contribute to this continuous improvement.
Marketing
Marketing cookies are used to track visitors on web pages. The intention is to show ads relevant and attractive to the individual user, and therefore more valuable to publishers and third-party advertisers.