Region AMERICA

    Standby Power

    STANDBY DIESEL

    STANDBY DIESEL

    Find your generator set
    Version

    Model

    HDI-515V T6U

    Three phase | Diesel | Level 1 Stationary Standby

    Model

    Powered by VOLVO

    Alternator STAMFORD

    Emissions TIER II

    PRP
    ESP
    COP
    Power kVA
    644
    Power kW
    515
    Voltage Frequency Phase Alternator Connection type Generator set data sheet
    120/208 V 60 Hz Three phase HCI534E Star - Parallel Download
    120/208 V 60 Hz Three phase HCI534F Star - Parallel Download
    120D/240 V 60 Hz Three phase HCI534E Delta-series Download
    120D/240 V 60 Hz Three phase HCI534F Delta-series Download
    138/240 V 60 Hz Three phase HCI534E Star - Parallel Download
    138/240 V 60 Hz Three phase HCI534F Star - Parallel Download
    277/480 V 60 Hz Three phase HCI534D Star-series Download
    277/480 V 60 Hz Three phase HCI534E Star-series Download
    347/600 V 60 Hz Three phase HCI534D Star-series Download
    347/600 V 60 Hz Three phase HCI534E Star-series Download
    • Engine Specifications 1,800 r.p.m.
    • Rated Engine Output: 485kW prp ; 546kW standby
    • Manufacturer: VOLVO
    • Model: TAD 1641GE
    • Engine Type: 4-stroke diesel
    • Injection Type: Direct
    • Aspiration Type: Turbocharged and after-cooled
    • Number of cylinders and arrangement: 6-L
    • Bore and Stroke: 5.67 x 6.5 in
    • Displacement: 983.64 CID
    • Cooling System: Coolant
    • Lube Oil Specifications: VDS-2, ACEA:E3, E5; API CG-4
    • Compression Ratio: 16.5:1
    • Fuel Consumption ESP: 35.22 Gal/h
    • Fuel Consumption 100% PRP: 30.69 Gal/h
    • Fuel Consumption 75 % PRP: 22.57 Gal/h
    • Fuel Consumption 50 % PRP: 15.2 Gal/h
    • Fuel Consumption 25 % PRP: 8.49 Gal/h
    • Lube oil consumption with full load: 0.193
    • Total oil capacity including tubes, filters 12.68 Gal
    • Total coolant capacity: 15.85 Gal
    • Governor Type Electrical
    • Air Filter Type Dry
    • Inner diameter exhaust pipe: 160 in

    • Generator: STAMFORD
    • Model: HCI534E
    • Poles: 4
    • Connection type (standard): Star - Parallel
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534D
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534D
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Star - Parallel
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Star - Parallel
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534E
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534E
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534E
    • Poles: 4
    • Connection type (standard): Delta-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)

    • Generator: STAMFORD
    • Model: HCI534F
    • Poles: 4
    • Connection type (standard): Delta-series
    • Mounting type: S-1 14"
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)
    • - EXHAUST SYSTEM.
    • Maximum exhaust temperature: 894.2 ºF
    • Exhaust Gas Flow: 233,924.00 cfs
    • Maximum allowed back pressure: 40.10 inH2O
    • Heat dissipated by exhaust pipe: 696,63 KCal/Kwh
    • - NECESSARY AMOUNT OF AIR.
    • Intake air flow: 1,617 scfm
    • Cooling Air Flow: 24,325 scfm
    • Alternator fan air flow: 2,780 scfm
    • - STARTING SYSTEM.
    • Starting power: 7 kW
    • Starting power: 9.39 HP
    • Auxiliary Voltage: 24 Vdc
    • Starter current peak: 700 A
    • Nominal starter current: 280 A
    • - FUEL SYSTEM
    • Fuel Oil Specifications: Diesel
    • - DIMENSIONS.
    • Length: 207.09 in
    • Height: 93 in
    • Width: 68.5 in
    • Maximum shipping volume: 762.8 ft3
    • Weight with liquids in radiator and sump: 9,299 Lbs
    • Sound pressure level: 78 ± 2.4 dB(A)@7m

    Dimensions

    Dimensions
    Length526207.1
    Width17468.5
    Height23692.9

    Weight

    Weight

    Weight with fluids in radiator and crankcase

    4,218

    9,301